4
69
K TECHNICAL SPECIFICATIONS
Use indicatively, subject to change.
* Conform EN 14511-2007, based on single duct use
** Moisture removal at 27°C, 60% RH
*** See chapter B
Environmental information: This equipment contains fluorinated greenhouse
gases covered by the Kyoto Protocol. It should only be serviced or dismantled by
professional trained personnel.
This equipment contains R410A refrigerant in the amount as stated in the table
above. Do not vent R410A into atmosphere: R410A, is a fluorinated greenhouse
gas with a Global W
arming Potential (GWP) = 1975.
Waste electrical products should not be disposed with household waste. Please
recycle where facilities exist. Check with your local authority or retailer for
recycling advice.
Model
P 227 PH 227
Cooling capacity* W 2700 2700
A A
2.62 2.62
Heating capacity*
W 2700
Heating performance
C
COP*
2.61
Power consumption
kW 1.03 1.03
Current nom.
A 5 5
Mains V/Hz/Ph
230 / 50 / 1 230 / 50 / 1
Air delivery max.
m
3
/h
300 300
Dehumidification max. **
L/24h 26 26
For rooms up to
m
3
65- 90 65 - 90
rotary rotary
Refrigerant
type/gr R-410A / 650 R-410A / 650
Thermostatic range
°C 16 - 32 16 - 27
3 3
Noise level
dB (A) 40-51 40-51
Dimensions (w x h x d)
mm 436 x 745 x 390 436 x 745 x 390
Weight
kg 30
31
IP 20 IP 20
Yes Yes
Yes Yes
Yes Yes
Sterionizer
TM
+ & - Ions / sec
1,0 * 10
9
1,0 * 10
9
EVS*** Yes Yes
250V, T3.15A 250V, T3.15A
Remote control
Bacterio-static 3M
TM
HAF filter + screen filter
Active carbon filter
Unit protection
Fuse rating
EE Class
EER*
Compressor type
Fan speed positions